UCSC-C240-M4S2 Technical Specifications
Cisco UCS C240 M4 High-Density Rack Server
Bay Provided
Form Factor :2.5″ SFF
Free Qty :16
Total Qty :16 Bays
Chassis
Form Factor :Rack-mountable
Hot-Swap Bays Qty :16
Manufacturer Form Factor :Rack-mountable
Server Storage Bays :Hot swap
Server Swappable Drive Form Factor :2.5″
Server Swappable Drive Form Factor (metric) :6.4 cm
Server Swappable Drive Interface :SATA/SAS
Dimensions & Weight
Depth :29.1 in
Height :3.4 in
Width :17.6 in
Display
Type :None.
Environmental Parameters
Humidity Range Operating :10 – 90% (non-condensing)
Max Operating Temperature :95 °F
Min Operating Temperature :41 °F
Expansion Bays
Form Factor (metric) :6.4 cm SFF
Type :Hot-swap
Expansion Slots
Type :CPU
Type :DIMM 288-pin
Type :SD card (internal)
Hard Drive
Type :No HDD
Hard Drive (2nd)
Type :None
Hard Drive (3rd)
Type :None
Header
Brand :Cisco
Compatibility :PC
Manufacturer :Cisco Unified Computing
Model :C240 M4 High-Density Rack Server (Small Form Factor Hard Disk Drive Model)
Packaged Quantity :1
Product Line :Cisco UCS
Interface Provided
Connector Type :RJ-45
Type :Serial
Location :1 in front
Type :KVM
Qty :1
Type :VGA
Qty :2
Type :USB 3.0
Type :LAN (Gigabit Ethernet)
Type :Management (NIC)
Mainboard
Chipset Type :Intel C612
Processor Socket :LGA2011-v3 Socket
Miscellaneous
Color Category :Silver
Compliant Standards :AS/NZS 60950-1, BSMI CNS 13438 Class A, CISPR 22 Class A, CISPR 24, CSA C22.2 No. 60950-1 Second Edition, Directive 2004/108/EC, Directive 2006/95/EC, EN 300 386, EN 300386, EN 60950-1 Second Edition, EN 61000-3-2, EN 61000-3-3, EN55022 Class A, EN55024, GB4943.1-2001, ICES-003 Class A, IEC 60950-1 Second Edition, KN22 Class A, KN24, UL 60950-1, UL 60950-1 Second Edition
Height (Rack Units) :2
Included Accessories :SAS expander
Networking
Data Link Protocol :Ethernet, Fast Ethernet, Gigabit Ethernet
Ethernet Controller(s) :Intel I350
Ethernet Ports :2 x Gigabit Ethernet
Features :PXE support
Optical Storage
Drive Type :No optical drive
Type :None
Optical Storage (2nd)
Type :None
OS Provided
Type :No operating system
Power Device
Installed Qty :0
Max Supported Qty :2
Power Redundancy :Optional
Type :Power supply – hot-plug
Printer
Type :None
Processor
Max Supported Qty :2
Server Scalability :2-way
Type :No CPU
Upgradability :Upgradable
RAM
Data Integrity Check :ECC
Empty Slots :24
Features :Dual rank, Load-Reduced DIMM (LRDIMM), Memory Mirroring, Registered, Single rank
Form Factor :DIMM 288-pin
Installed Size :0 GB
Max Supported Size :768 GB
Slots Qty :24 DDR4 Slots
Technology :DDR4 SDRAM